The service factor of an electric motor is determined by ____.


A) National Electrical Code
B) National Electrical Manufacturers Association code
C) motor's reserve capacity
D) the required wire size supplying power to the motor

Correct Answer

verifed

verified

The best way to repair a defective relay is by ____________________.

Correct Answer

verifed

verified

Magnetic overload devices are the most accurate type of device for electrical protection.

Correct Answer

verifed

verified

Auxiliary contacts are usually rated at a lower amperage than the contactor's primary contacts.

Correct Answer

verifed

verified

An inherent motor protector is a ____.


A) circuit breaker
B) motor starter overload
C) thermally activated device in the motor winding
D) line fuse

Correct Answer

verifed

verified

The locked rotor amperage, LRA, of a motor is typically five times higher than the full load amperage, FLA, of the motor and can be as high as seven times the FLA.

Correct Answer

verifed

verified

If a normally operating motor draws 75 amps on startup, it will most likely draw ____________________ amps when running.

Correct Answer

verifed

verified

Which of the following overload devices is not affected by ambient temperature?


A) solder pot
B) magnetic
C) bimetal
D) time-delay fuse

Correct Answer

verifed

verified

Technician "A" says that if you take a voltage reading from terminal "L1" to terminal "T1" on a contactor whose coil is energized, you should read zero volts. Technician "B" says that contactors can only have normally open contacts. Which of the following statements is correct?


A) Technician "A" is correct. Technician "B" is correct.
B) Technician "A" is correct. Technician "B" is incorrect.
C) Technician "A" is incorrect. Technician "B" is correct.
D) Technician "A" is incorrect. Technician "B" is incorrect.

Correct Answer

verifed

verified

A set of contacts are closed when the relay is energized. These contacts are classified as normally closed.

Correct Answer

verifed

verified

Beside maintaining pressure on the contacts for current carrying capacity, the pressure springs have a second important function. This is to ____.


A) keep the contacts in line
B) help obtain equal contacts against the stationary contacts
C) slow down the pull of the armature into place to reduce the noise
D) increase the power required to close the contacts

Correct Answer

verifed

verified