Filters
Question type

Study Flashcards

Cooling towers are rated in terms of


A) approach
B) range
C) both of the mentioned
D) none of the

Correct Answer

verifed

verified

When humidity ratio of air ____ air is said to be dehumidified.


A) increases
B) decreases
C) remains constant
D) none of the mentioned

Correct Answer

verifed

verified

why is an analyser-rectifier combination is used in absorption refrigeration cycle?


A) to increase the amount of water vapour in ammonia vapour
B) to decrease the amount of water vapour in ammonia vapour
C) to eliminate the water vapour from ammonia vapour
D) all of the mentioned

Correct Answer

verifed

verified

Which type of fins are the most commonly used fin type in condensers?


A) annular fin
B) plate type fins
C) tube fin
D) extended double pipe

Correct Answer

verifed

verified

In traditional Refrigerators in home appliances, what is the type of condenser used?


A) natural convection type
B) forced convection type
C) furnace type
D) rotary condensers

Correct Answer

verifed

verified

A

In traditional Air conditioners in home appliances, what is the type of condenser used?


A) natural convection type
B) forced convection type
C) flash type
D) rotary condensers

Correct Answer

verifed

verified

Critical pressure ratio is ratios of pressures at______________discharge.


A) minimum
B) none of the mentioned
C) optimum
D) maximum

Correct Answer

verifed

verified

When unsaturated air flows over a sheet of water in an insulated chamber


A) specific humidity of air decreases
B) the water evaporates
C) both air and water are cooled during evaporation
D) all of the mentioned

Correct Answer

verifed

verified

Evaporative condensers are used in places where water is _________


A) scarce
B) plenty
C) moderately available
D) sufficient

Correct Answer

verifed

verified

What is the meaning of heat rejection ratio (HRR) of a condenser?


A) ratio of heat rejected to the heat absorbed
B) ratio of heat absorbed to the heat rejected
C) ratio of heat required to the heat lost
D) ratio of heat wasted in a cycle to the heat absorbed

Correct Answer

verifed

verified

The wet bulb temperature is the ____ temperature recorded by moistened bulb.


A) lowest
B) highest
C) atmospheric
D) none of the mentioned

Correct Answer

verifed

verified

A

The ratio of the useful heat drop to the isentropic heat drop is called______________      


A) condenser efficiency
B) nozzle efficiency

Correct Answer

verifed

verified

The vapour going to condenser is ____ in temperature and ____ in ammonia.


A) higher, less
B) higher, richer
C) lower, less
D) lower, richer

Correct Answer

verifed

verified

In fountains the type of nozzle used is


A) none of the mentioned
B) turbulent jet
C) high speed nozzle
D) laminar jet

Correct Answer

verifed

verified

Water is used as a ____ in air conditioning units.


A) absorbent
B) refrigerant
C) absorbent and refrigerant
D) none of the mentioned

Correct Answer

verifed

verified

Shell and coil type condensers have a capacity at around ________


A) 10 tr
B) 20 tr
C) 30 tr
D) 50 tr

Correct Answer

verifed

verified

Double pipe water cooling condensers have a capacity at around ________


A) 10 tr
B) 20 tr
C) 30 tr
D) 50 tr

Correct Answer

verifed

verified

A

Evaporative condensers combine the features of a _____________ in a single unit.


A) cooling tower and water-cooled condenser
B) falling tower and water-cooled condenser
C) cooling tower and air condenser
D) rising film tower and water-cooled condenser

Correct Answer

verifed

verified

An increase in diameter means a _________ heat transfer coefficient.


A) larger
B) smaller
C) zero
D) infinite

Correct Answer

verifed

verified

In evaporative condensers, ___________ used to extract heat from the condensing refrigerant.


A) air is
B) both air and water are
C) water is
D) either air or water is

Correct Answer

verifed

verified

Showing 1 - 20 of 25

Related Exams

Show Answer